XAPP589 - v2.1-When using the VCXO secondary clocking scheme, pre_opt_design.tcl errors out

描述

When I use the VCXO secondary clocking scheme and run pre_opt_design.tcl, the following error occurs:

[Vivado 12-180] No cells matched 'get_cells -filter {PRIMITIVE_SUBGROUP == gt} -of [get_pins -leaf -filter {DIRECTION == OUT} -of [get_nets -of [get_pins -leaf -filter {DIRECTION == IN && IS_ENABLE == 0} -of [get_cells -of [get_pins -leaf -filter {DIRECTION == OUT} -of [get_nets -of [get_pins -of [get_cells teng_sidei/picxo_top_wrapper_teng/Inst_picxo_top] -filter {NAME =~ *txoutclk_i}]]]]]]]'.

解决方案

The secondary clocking scheme is as follows:

This error is a known issue, please use the modified Tcl script attached to the end of this answer record (pre_opt_design.tcl).

This issue is fixed in v2.2.

附件

文件名 文件大小 File Type
pre_opt_design.tcl 6 KB TCL

链接问答记录

主要问答记录

Answer Number 问答标题 问题版本 已解决问题的版本
56136 XAPP589 - XAPP1241 - All Digital VCXO Replacement (PICXO) - Design Assistant / Master Answer Record N/A N/A