AR# 58647

|

MIG 7 Series DDR3 - Unable to derive 150 MHz input clock frequency

描述

Version Found: MIG 7 Series v2.0 Rev 2
Version Resolved: See (Xilinx Answer 54025)

When generating MIG Controller with DDR3 clock frequency 400 MHz, input clock 150 MHz is not being shown in the drop-down list. However, this configuration should be allowed as all MIG clock requirements are met.

解决方案

The Clocking Wizard is run in the background of the MIG GUI to determine the allowable input clock frequencies. The MIG GUI operates in picoseconds, but the Clocking Wizard operates in MHz which causes rounding errors when converting from picoseconds to MHz.

To work around the issue for MIG v2.0 and newer IP, the attached patch must be applied. Instructions for applying the patch can be found inside of the ar58647.zip file.

Revision History
12/19/2013 - Initial release

 

附件

文件名 文件大小 File Type
ar58647.zip 6 MB ZIP

链接问答记录

主要问答记录

Answer Number 问答标题 问题版本 已解决问题的版本
54025 MIG 7 Series - IP Release Notes and Known Issues for Vivado N/A N/A
AR# 58647
日期 12/20/2013
状态 Active
Type 已知问题
器件
IP
People Also Viewed