AR# 52285

|

LogiCORE IP Video Scaler v6.00.a/v7.00.a/v7.01.a/v8.0/v8.1 - Why do the INTC_IF interface register and pins not behave as described in the documentation?

描述

Why do the INTC_IF interface register and pins not behave as described in the documentation?

解决方案

This is a known issue.

INTC_IF register interface pins do not work as expected, the affected pins/registers are listed below :

  • intr_coef_mem_rdbk_rdy
  • eol_error
  • sof_error 
  • intr_coef_wr_error

This issue affects the Video Scaler v6.00.a, v7.00.a, v7.01.a, v8.0 and v8.1.  

It is recommended that users ignore the INTC_IF interface.

If you are following the Coefficient readback process documented in PG009 LogiCORE IP Video Scaler Product Guide, you should wait two frames before attempting to read back the coefficients, rather than polling the intr_coef_mem_rdbk_rdy pin or register.

For more details on the eol_error issue, see (Xilinx Answer 52664)
For a detailed list of LogiCORE IP Video Scaler Release Notes and Known Issues, see (Xilinx Answer 31958).
For a detailed list of LogiCORE IP Video Scaler Release Notes and Known Issues, Vivado 2013.1 and newer tool versions see (Xilinx Answer 54540).