AR# 47677

|

ChipScope Pro ILA - ChipScope core might fail timing when using a trigger width of greater than 256 and a depth of more than 32K

描述

This answer recorddiscusses a known issue with the ChipScope ILA core and the ISE design tools.

解决方案

If you are using the ILA core in ISE Design Tools 14.1 and later with a trigger width of greater than 256 bits and a depth of more than 32K, the ILA core can fail timing. This is a known issue that will be fixed in a later release of the ChipScope tools.

To work around the issue, use a trigger width of less than 256 and a depth of less than 32K.

链接问答记录

主要问答记录

Answer Number 问答标题 问题版本 已解决问题的版本
47769 14.x ChipScope Pro and 2012.x Vivado Debug - Known Issues for the 14.x ChipScope Pro and 2012.x Vivado Debug tools N/A N/A
AR# 47677
日期 07/17/2012
状态 Active
Type 已知问题
Tools
IP