Versal IBERT GTY shows the incorrect link speed in the Serial I/O Link Status column.
Below is an example from a 25.78125 Gbps design, where the status column shows 26.142 Gbps in the hardware manager.
Version Found: Vivado 2021.1
Version Resolved and other Known Issues: See (Xilinx Answer 75716)
This issue has been observed in 2021.1 but was not present in earlier Vivado releases.
Answer Number | 问答标题 | 问题版本 | 已解决问题的版本 |
---|---|---|---|
75716 | Versal ACAP GTY Transceivers Wizard and IBERT - Master Release Notes and Known Issues | N/A | N/A |