AR# 7133

|

7.1i Timing Analyzer/TRACE (trce) - "ERROR: Trace - Invalid speed 'min' specified on command line" or ""ERROR:TimingAnalyzer - "-min" is not a valid speed grade for this device

描述

General Description:

When I generate STAMP data for minimum timing values in TRACE or a minimum timing report, the following error occurs:

"ERROR: Trace - Invalid speed 'min' specified on command line."

The following fatal error then occurs:

"Fatal Error: Command failed for target."

解决方案

The "-s min" option is supported only in the specific family mentioned in (Xilinx Answer 4506).

You can only use the "-s min" option for fully routed designs. If a design contains any unrouted signals, this error will occur.

For more information, see (Xilinx Answer 4506) and (Xilinx Answer 6067).

AR# 7133
日期 01/18/2010
状态 Archive
Type 综合文章
People Also Viewed