JESD204 PHY (v3.4) - txoutclk / rxoutclk clocks not running

描述

For the JESD204 PHY (v3.4), if the "Master Channel" is set to any channel other than 1, txoutclk and rxoutclk clocks can be seen to not be running.

This will only affect customers who meet the following criteria:

  • Using Vivado 2017.2
  • Using an UltraScale+ device with a GTHE4 or GTYE4 transceiver
  • Using txoutclk or rxoutclk output clocks
  • "Additional transceiver control and status ports" or "AXI4-Lite Management Interface" are enabled
  • "Master Channel" is set to a value other than 1

解决方案

To work around this issue, ensure "Master Channel" is set to 1 in the JESD204 PHY GUI.

This will be fixed in the next revision of the core to be released with Vivado 2017.3 (v4.0).