Why does Video Timing Controller Generator reset early in relation to the Blanking Signals, if both the detector and the generator are enabled?
This only happens when the Detector and the Generator are both enabled, and the Detector is set up to only detect the Blanking inputs, but not the Sync inputs.
This is a known issue in the Video Timing Controller v5.01.a.
It is fixed in the Video Timing Controller v5.01.a Rev2 or later pcore patch, and in the Video Timing Controller v6.0.
For a detailed list of LogiCORE IP Video Timing Controller Release Notes and Known Issues, see (Xilinx Answer 32754).
Answer Number | 问答标题 | 问题版本 | 已解决问题的版本 |
---|---|---|---|
32754 | LogiCORE IP Video Timing Controller - Release Notes and Known Issues | N/A | N/A |
52846 | LogiCORE IP Video Timing Controller v5.01.a - Patch Updates for the Video Timing Controller | N/A | N/A |
54541 | LogiCORE IP Video Timing Controller - Release Notes and Known Issues for Vivado 2013.1 and newer tool versions | N/A | N/A |
AR# 54611 | |
---|---|
日期 | 12/23/2014 |
状态 | Archive |
Type | 综合文章 |
IP |