AR# 54223

|

Artix-7 - Bitstream compatibility between Production and GES silicon

描述

What is required to ensure bitstream compatibility between GES and Production Silicon for the Artix-7 family?

解决方案

The version of software required to create a Production bitstream is documented in the Artix-7 Data Sheet DS181, in the Device Production Software and Speed Specification Release table. For example, the XC7A100 -3 speed grade requires ISE 14.4 and Vivado 2012.4 version design tools with the 14.4/2012.4 device pack of  v1.07 or later. A bitstream created with this version of tools will support GES and Production Silicon.

Other issues that might need to be addressed to ensure the bitstream compatibility:

  • Design Advisory for Artix-7 FPGA GTP Transceivers - RX Reset Sequence Requirement for Production Silicon; see (Xilinx Answer 53561).
  • Design Advisory for MIG 7 Series DDR3/DDR2 - Required calibration patch for v1.7 and v1.8; see (Xilinx Answer 53420).

链接问答记录

主要问答记录

Answer Number 问答标题 问题版本 已解决问题的版本
51900 Artix-7 FPGA AC701 Evaluation Kit - Known Issues and Release Notes Master Answer Record N/A N/A
AR# 54223
日期 06/03/2013
状态 Active
Type 综合文章
器件
People Also Viewed