status

The status command displays the status of the debug IPs on the card. Currently, this command can read and report the status of SDx™ performance monitor (SPM) and lightweight AXI protocol checker (LAPC) debug IPs. For more information on adding SPM counters and LAPC in your design, see SDAccel Environment Debugging Guide (UG1281).

Below are the available options. If you are running without arguments, it shows the list of available debug IPs.

  • --spm (Optional): Returns the value of the SPM counters. This option is only applicable if the xclbin was compiled with the necessary profiling options.
  • --lapc (Optional): Returns the values of the violation codes detected by the LAPC. This option is only applicable if xclbin was compiled with necessary option to insert AXI protocol checkers at the AXI ports of the compute units.

An example output of the following command is shown below:

$ xbutil status
INFO: Found total 1 card(s), 1 are usable
Number of IPs found: 6
IPs found [<ipname>(<count>)]: spm(2) tracefunnel(1) monitorfifolite(1) monitorfifofull(1) accelmonitor(1) 
Run 'xbutil status' with option --<ipname> to get more information about the IP
INFO: xbutil status succeeded.

An example output using the --spm option is shown below:

$ xbutil status --spm
INFO: Found total 1 card(s), 1 are usable
SDx Performance Monitor Counters
CU Name                 AXI Portname  Write Bytes  Write Trans.  
interconnect_aximm_host M00_AXI       8192         16              
simple_1                M_AXI_GMEM    4096         1024                
CU Name                 Read Bytes  Read Trans.  Outstanding Cnt 
interconnect_aximm_host 4096        1            0                    
simple_1                4096        1024         0                       
CU Name                 Last Wr Addr  Last Wr Data  Last Rd Addr
interconnect_aximm_host 0x0           0             0xe00               
simple_1                0x0           0             0xffc                  
CU Name                 Last Rd Data    
interconnect_aximm_host 1483476076      
simple_1                1062897         
INFO: xbutil status succeeded.

When there are no debug IPs in the xclbin, you will see a similar output as shown below:

INFO: Found total 1 card(s), 1 are usable
INFO: Failed to find any debug IPs on the platform. Ensure that a valid bitstream with debug IPs (SPM, LAPC) is successfully downloaded. 